自動(dòng)灌膠機的操作守則!

瀏覽:0
  一、自動(dòng)灌膠機開(kāi)機流程
  I. Start-up process of automatic glue filling machine
  1、檢查灌膠區,如有雜物、工具等,必需清算潔凈;
  1. Check the glue-filling area. If there are any sundries and tools, it must be cleaned up.
  2、檢查緊縮空氣能否在正常范圍,電源能否滿(mǎn)足請求;
  2. Check whether the compressed air can be in the normal range and whether the power supply can meet the requirements.
  3、鑰匙開(kāi)關(guān)右轉,給機器通電;
  3. Turn the key switch right and power the machine.
  4、裝混合管前測試雙液閥動(dòng)作能否正常,出膠量能否精確,灌膠的產(chǎn)品或膠水與上一次的不同,要停止配比調試;
  4. To test whether the action of double liquid valves is normal, whether the quantity of glue is accurate, and whether the product or glue of glue filling is different from that of the last time, it is necessary to stop the ratio debugging.
  5、裝混合管后測試動(dòng)態(tài)攪拌能否正常,同時(shí)吐出AB膠,確認混合管充溢且沒(méi)有氣泡;
  5. Test whether the dynamic stirring is normal after installing the mixing tube, and vomit AB glue at the same time to confirm that the mixing tube is full and there is no bubble.
  6、擺放產(chǎn)品,編輯程序或起點(diǎn)位置,在關(guān)膠狀態(tài),考證三軸的運轉途徑能否滿(mǎn)足請求;
  6. Place the product, edit the program or the starting point, check the running way of the three axes to satisfy the request.
  7、按主畫(huà)面的“關(guān)膠”鍵,使其顯現“開(kāi)膠”,按綠色啟動(dòng)按鈕,停止消費, 需求暫停,按綠色按鈕,緊急狀況,按急停按鈕。
  7. Press the "off glue" button on the main screen to make it appear "open glue", press the green start button, stop consumption, stop demand, press the green button, press the emergency button, press the emergency stop button.
  二、關(guān)機流程
  II. Shutdown process
  1、假如開(kāi)啟了循環(huán)功用,一個(gè)產(chǎn)品灌膠時(shí),關(guān)閉循環(huán)功用;
  1. If the circulation function is opened, the circulation function is closed when a product is glued.
  2、有自動(dòng)清洗功用的,運轉自動(dòng)清洗。無(wú)自動(dòng)清洗功用的,拆下混合管,同時(shí)出AB膠3-5秒,用碎布擦拭潔凈雙液閥閥頭;3、關(guān)閉電源,清算機臺,清洗混合管等。
  2. With the function of automatic cleaning, it can be operated and cleaned automatically. If there is no automatic cleaning function, remove the mixing pipe and give out AB glue for 3-5 seconds at the same time, wipe clean the valve head of the double liquid valve with rag; 3. Close the power supply, clean the mixing pipe, etc.
雙組份打膠機
  三、短時(shí)停機
  3. Short-term shutdown
  1、假如開(kāi)啟了循環(huán)功用,一個(gè)產(chǎn)品灌膠時(shí),關(guān)閉循環(huán)功用;
  1. If the circulation function is opened, the circulation function is closed when a product is glued.
  2、開(kāi)啟自動(dòng)排膠功用,留意自動(dòng)排膠時(shí)間,要在膠水變稠前排膠。
  2. Open the function of automatic dispensing, pay attention to the time of automatic dispensing, and dispel glue before the glue thickens.
  四、真空灌膠機灌膠過(guò)程中留意事項
  IV. Notices in the Process of Vacuum Filling Machine Filling
  1、在套上“混合管”之前,進(jìn)入“配膠畫(huà)面”,檢測AB膠的出膠能否順暢,出膠量能否精確;
  1. Before putting on the "mixing pipe", enter the "glue matching screen" to check whether the glue of AB glue is smooth and the glue quantity is accurate.
  2、檢查“混合管、螺旋葉片、針頭、針嘴”能否潔凈,有無(wú)異物梗塞;
  2. Check the cleanliness of "mixing tube, spiral blade, needle and needle nozzle" and whether there is foreign body infarction.
  3、在產(chǎn)品灌膠前應把5秒AB混合膠的出膠量記載好,在產(chǎn)品灌膠過(guò)程中約每?jì)尚r(shí)檢測一次AB膠重量能否與記載的值分歧,假如變動(dòng)過(guò)大,要馬上停機檢查,否則膠水可能不干;
  3. Record the amount of 5 seconds AB mixed glue before product filling. Check whether the weight of AB glue differs from the recorded value every two hours during product filling. If the change is too big, stop the machine immediately to check. Otherwise, the glue may not dry.
  4、親密留意AB膠桶的膠量,AB膠桶中在沒(méi)有膠水狀況下空動(dòng)行,會(huì )對供膠局部有所損傷;
  4. Pay close attention to the amount of glue in AB bucket. If AB bucket moves without glue, it will damage the glue supply part.
  5、放置產(chǎn)品到夾具上時(shí),要放在相同的位置上;
  5. Place the product on the fixture in the same position.
  6、依據膠水固化時(shí)間,暫時(shí)灌膠十五分鐘以上,恢復灌膠時(shí)應檢測 AB混合膠吐出重量;
  6. According to the curing time of glue, temporary glue filling should be more than 15 minutes. When restoring glue filling, the vomiting weight of AB mixed glue should be detected.
  7、依據膠水固化時(shí)間,暫停灌膠約三非常鐘以上,要取下混合管停止清洗。
  7. According to the curing time of glue, the filling time should be suspended for more than 30 minutes, and the mixing pipe should be removed to stop cleaning.